Abstract
ISO 10816-4:2009 establishes specific provisions for evaluating the severity of in-situ, broad-band vibration measured radial (i.e. transverse) to the shaft axis on all main bearing housings or pedestals and in the axial direction on thrust bearings. These are in terms of:
- vibration under normal steady-state operating conditions;
- vibration during other (non-steady-state) conditions when transient changes are taking place, including run up or run down, initial loading and load changes;
- changes in vibration which can occur during normal steady-state operation.
ISO 10816-4:2009 is applicable to heavy-duty gas turbine sets used in electrical and mechanical drive applications, with fluid-film bearings, outputs greater than 3 MW and an operating speed range under load between 3 000 r/min and 30 000 r/min.
General information
-
Status: WithdrawnPublication date: 2009-10Stage: Withdrawal of International Standard [95.99]
-
Edition: 2Number of pages: 16
-
Technical Committee :ISO/TC 108/SC 2
- RSS updates
Life cycle
-
Previously
WithdrawnISO 10816-4:1998
-
Now
-
00
Preliminary
-
10
Proposal
-
20
Preparatory
-
30
Committee
-
40
Enquiry
-
50
Approval
-
60
Publication
-
90
Review
-
95
Withdrawal
Amendments
Provide additional content; available for purchase; not included in the text of the existing standard.WithdrawnISO 10816-4:2009/Amd 1:2017
-
00
-
Revised by
PublishedISO 20816-4:2018